Floor Heating

nVent RAYCHEM underfloor heating brings comfort and reduces heating costs
Floor-Heating-Commercial
  • Electric underfloor heating is installed close to the floor surface, resulting in quick room warm-up.
  • Uniform heat distribution allows for a lower thermostat setting (2°C) without any loss of comfort.

Heat radiation from a conventional heating system with radiators. Large temperature variations (18–65°C) in the room.

Heat radiation from an underfloor heating system. Small temperature variations (20–25°C) and heat where you need it.

Tek-HeatRad-Man Tek-HeatRad-Vrouw
  • During spring or autumn, turn off the conventional heating yet keep floors warm and cozy
  • RAYCHEM floor heating systems provide comfortable heat to all floor types.
  • Complete room heating or comfort heating to complement existing heating system
  • Ideal for renovation projects because of low construction height, but also suitable for new construction.
    • Bathrooms, kitchens, entrance halls, living rooms, leisure rooms, conservatories… in residential buildings
    • Guest rooms in hotels, nursery homes and hospitals, playgrounds in kindergartens, dressing rooms in sports facilities
How does the system work?
  1. The floor and/or ambient sensor(s) sense a temperature below the set point(s).
  2. The thermostat switches the floor heating system on.

A smart floor heating solution for every need will heat the floor evenly until the desired temperature is reached.

  • T2Red, the intelligent, self-regulating, underfloor heating solution
  • T2Red + T2Reflecta, the energy-saving, self-regulating underfloor heating system
  • T2QuickNet, the thin, self-adhesive heating mat
  • T2QuickNet + Isolecta, the insulated, thin heating mat solution
  • T2Blue, the robust, in screed, cable heating solution
  • T2Blue + Isolecta, the insulated, robust, in screed heating cable solution
  • CeraPro + Isolecta, the insulated, robust, ultra thin, heating cable solution for installation directly in tile adhesive.

How to select the right underfloor heating system for you?
From the thin T2QuickNet mat for renovation to energy-saving T2Red + T2Reflecta system: select the right system and calculate which configuration fits the room surface.

How to Install RAYCHEM underfloor heating
Tips and complete installation guidelines for installation of RAYCHEM's complete underfloor heating systems.

The floor heating that suits you – in renovation or construction

Mother-Child

Invisible comfort & safety
Floor heating systems do not take up any space. Rugs, furniture and carpets can be placed wherever desired.

  • It can be installed on most stable sub floors (wood, plaster and concrete).
  • under all floor coverings such as tiles, marble and laminate.

Dry floors are hygienic and easy to clean as the dust doesn’t ‘stick’ to the floor.
There is less air movement, hence less dust.
Wet floors in bathrooms will also dry much faster.
nVent RAYCHEM systems emit the lowest possible electro-magnetic fields thanks to their twin-wire construction.

Ease of use

A complete product bag to suit every need !
RAYCHEM floor heating products are available in different shapes, sizes and power outputs to fit all room sizes, shapes and heat requirements. Make a fast product selection using the RAYCHEM design wizard or the request form for a free, detailed design. Our engineers can advise on product selection, material list and 2D or 3D installation plans. You can also get in touch with one of our Certified Pro installers near you to help choose and install the right product.
RAYCHEM floor heating has been tested and approved to be used with common building materials. Go to the compatible building materials selector to choose the right products from the major manufacturers.

Fast installation

  • No connections to make on the job site.
  • Constant-wattage cables and mats are pre-terminated and tested in the factory.
  • Dual-conductor cables have just one power connection.
  • The self-regulating cable can be cut to length & directly connected to the thermostat.
  • Our floor heating thermostats integrate well with other switch gear in the room and are compatible with switch gear frames of major manufacturers.
Energy efficient and maintenance free operation
Interior1_Thumbnail

Lower the room thermostat by 2 degrees without losing the comfort feeling.
Uniform heat distribution allows for a lower thermostat setting without any loss of comfort. Electric floor heating systems are installed close to the floor surface to provide heat quickly. The systems are switched on when needed only. The programmable NRG-TEMP thermostat can learn when it needs to switch on to make the floor warm when needed.
Our self-regulating cable lowers its heat output automatically when it senses other heating sources e.g. sun shining on the floor near a window.

Insulation boards can reduce energy consumption by more than 20%: All RAYCHEM systems can be combined with an insulation layer for additional energy savings. Insulation boards shorten the heat-up time. And they avoid downward heat losses on insufficiently insulated subfloors e.g. in older buildings.

Electric floor heating systems are almost maintenance free as there are no moving parts. All RAYCHEM floor heating systems come with a 12 year Total Care Warranty . It can even be extended to 20 years when the system is installed by a Certified Pro installer .

Smart Floor heating technology – adapted to suit your specific needs

T2Red - the intelligent floor heating solution

T2Red-Thumbnail

T2Red is a self-regulating underfloor heating cable for reduced height installation. The cable can be installed under any type of floor surfaces, including temperature sensitive floors, without a risk of overheating. The intelligent heating cable is ideal for improved living comfort in the entire house, from bathroom to children’s room.
  • Easy-to-design : one heating cable for all shapes of rooms.
  • Flexible : cut-to-length, no cold lead needed.
  • Ideal for renovation : reduced height (max. 8 mm).

T2Red + T2Reflecta

T2ReflectaPLAAT_Thumbnail

  • The energy-efficient system 20% extra energy saving through integrated insulation.
  • Even and adaptive heat distribution in floor.
  • Thanks to the self-regulating effect, there is no risk for overheating under carpets, furniture, etc.
  • Automatic self-regulating output depending on environment (more output in cold zones, less output in warm zones).
  • No measurable electro-magnetic fields.
  • Long life and maintenance free.
  • The cable can be installed under any type of floor surfaces, including temperature sensitive floors, without a risk of overheating.

Applications : Living rooms, kitchens, bathrooms, dining room, children’s room, conservatories
Top floor : Tiles, parquet, natural stone, laminate, carpet*
Sub floor : Cement screed; anhydrite screed, wooden floor, gypsum board, timber floor board, asphalt screed
*must be suitable for underfloor heating (maximum resistance to heat transfer 0,15 W/m²K)

System components
T2Red self-regulating heating cable
T2Reflecta plate:

  • With installation grooves
  • With insulation + integrated aluminum heat distribution layer
  • End plates
  • An insulated aluminum covered plate

T2QuickNet

T2QuickNet_Thumbnail

  • Self-adhesive, 3 mm thick underfloor heating mat for direct installation under ceramic tiles or natural stone.
  • Only 3 mm thick!
  • One cold lead (dual wire system)
  • Ideal as direct underfloor heating for embedding in tile adhesive or filler underneath the top floor
  • Maximum construction height including tiles is 15 mm

Applications Living rooms, kitchens, bathrooms, dining rooms, children’s rooms, conservatories
Top floor : Tiles, natural stone (max. 30 mm thick)
Sub floor : Cement screed, anhydrite screed, wooden floor*, Gypsum board, timber floor board
* T2QuickNet-160 is not suitable for direct installation on wooden subfloors


nVent RAYCHEM T2QuickNet + Isolecta

T2-Isolecta_Thumbnail

Benefits of total system
  • Up to 65% energy saving in heat up phase.
  • Heat up time significantly reduced.
  • Heat losses into the subfloor significantly reduced.

Applications : Living rooms, kitchens, bathrooms, dining room, conservatories
Top floor : Tiles, natural stone
Sub floor : Concrete, cement & wood System components
T2QuickNet mat Isolecta board:

  • Lightweight thermal insulation board
  • Water proof, dimensionally stable

CeraPro

CeraPro_Thumbnail

The Ultra thin (3 mm), robust underfloor heating cable solution for direct installation in adhesive under ceramic tiles or natural stone.

  • Only 3 mm thick!
  • Easy to install with innovative “Tape ‘n’ Mesh” fixing method.
  • Easy-Spool packaging to aid fast installation.
  • Ideal as direct under floor heating for embedding in tile adhesive
  • Typical construction height including tiles is 15 mm
  • Compliant with current IEC60800 regulations for heating cables.

Applications : Bathrooms, kitchens, conservatories and all other areas where tiled floors are installed
Top floor : Tiles, natural stone (max. 30 mm thick)
Sub floor : Cement screed, anhydrite screed, wooden floor*, Gypsum board, timber floor board, Isolecta floor heating insulation
*When installing CeraPro on a wooden subfloor, a maximum power output of 100W/m2 may not be exceeded


T2Blue

T2Blue_Thumbnail

  • T2Blue 10 W/m is a floor heating cable with constant power output of 10 W/m. It is a pre-terminated, dual conductor heater with a 2.5 m cold lead attached at one end.
  • T2Blue 20 W/m is a floor heating cable with constant power output of 20 W/m. It is a pre-terminated, dual conductor heater with a 2.5 m cold lead attached at one end.
  • T2Blue heating cables should be embedded in screed (50 mm).
  • T2Blue is the ideal floor heating system for installation in newly constructed buildings or renovation. This floor heating cable is typically applied in all new construction applications and for example in conservatories or cold rooms (refrigeration rooms).
  • T2Blue kits contain a digital electronic thermostat.
  • T2Blue comes in a handy installer friendly box containing some glue sticks for easy fixing to the subfloor and a conduit in which to install the sensor.

NRG-Temp Thermostat

NRGThermostat_Thumbnail

  • Large blue backlit display
  • Timer function, programmable each day per week in 30 minutes blocks
  • 2 selectable pre-programmes. (EcoH for e.g bathrooms; EcoO for e.g )
Charters Ascot luxury private residences
The Project

Charters Ascot, UK, is a development of luxury private residences in the grounds of a mansion house. The requirement was to supply underfloor, secondary heating to the living areas to supplement the main warm/cold air-conditioning, and fully integrate it with the building management system. There was also a requirement to provide heating to bathroom areas.

Key Challenges

Finding an energy efficient, easy to install solution, which would keep the floor height to a minimum.  A solution for wet areas, and for all areas, systems which could be integrated with the building management system.

Solution

T2Red heating cables and T2Reflecta insulation boards provided the right combination of comfort - even heat distribution across the entire floor surface - flexibility for further room decoration and reduced installation time. The floor heating system was integrated with the BMS, meaning no individual controllers were required. With the ease of use that comes with the T2Reflecta underfloor heating product this meant a great reduction in installation time and a reduction in onsite costs for the contractors.

Products

2000 m T2Red self regulating cable and T2Reflecta insulation boards
326 T2QuickNet mats (90W/m² and 160W/m²)

Related Products